Product Loading...

SIMpull CoilPAK™ Wire Payoff


New CoilPAK Testimonial!

The SIMpull® CoilPAK™ Wire Payoff provides greater versatility and efficiency to branch circuit installations,  eliminating the need for handling bulky spools and all of the setup and energy that go along with them. 

SIMpull® CoilPAK™ Wire Payoffs increase both safety and productivity by reducing the physical effort associated with material handling, pulling wire out of the package, and pulling wire through conduit. See Resources section for more information.

Work smarter with the SIMpull ® CoilPAKTM Wire Payoff by reducing the physical effort associated with material handling, setup, and pulling compared to traditional spools, increasing both safety and productivity on the job.

BENEFITS:

  • Stationary package design reduces pulling effort.
  • SIMpull NoLube® jacket further reduces pulling tension.
  • Designed to help reduce potential lifting/handling/pulling injuries.
  • Space saving, multi-wire Coil PAKTM payoffs with striped neutrals for greater efficiency and less handling.
  • No more broken spools or spool over-turn.

 

 

Southwire® SIMpull THHN® copper conductors as part of the SIMpull CoilPAK™ Wire Payoff are primarily used in conduit and cable trays for branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 volts. SIMpull THHN® copper conductors are designed to be installed without application of a pulling lubricant. These conductors have multiple ratings. Depending upon the product application, allowable temperatures are as follows:

  • THHN or T90 Nylon- Dry locations not to exceed 90° C
  • THWN-2- Wet or dry locations not to exceed 90° C or locations not to exceed 75° C when exposed to oil
  • TWN75- Wet locations not to exceed 75° C
  • MTW- Wet locations or when exposed to oil at temperatures not to exceed 60° C or dry locations not to exceed 90° C (with ampacity limited to that for 75° C conductor temperature per NFPA 79)
  • AWM- Dry locations not to exceed 105° C only when rated and used as appliance wiring material

Standards & References

Southwire® SIMpull THHN® copper conductors comply with the following:

  • ASTM - B3, B8, and B787 (19 Wire Combination Unilay-Stranded)
  • UL Standards 83, 758, 1063
  • CSA C22.2 No. 75, T90 Nylon/TWN75 Sizes through 1000 kcmil
  • NOM-ANCE 90° C
  • Federal Specification A-A-59544
  • NEMA WC-70 (ICEA S-95-658) Construction Requirements
  • National Electrical Code, NFPA 70
  • VW-1 - Sizes 14 through 1 AWG
  • FT1 - All Sizes
  • AWM - Sizes 14 through 6 AWG
  • MTW - Stranded Constructions Only
  • RoHS/REACH Compliant

Select a set of products below for more information:

  CONDUCTOR   ALLOWABLE AMPACITIES+
  Size (AWG or kcmil) No. of Conductors No. of Strands Nom. OD (mils) Insulation Thickness (mils) Jacket Thickness (mils) Nominal Total Weight (lbs/1000') Allowable Ampacity at 60C Allowable Ampacity at 75C Allowable Ampacity at 90C
580285 14 AWG 1 1 106 15 5 16 15 15 15
580170 14 AWG 1 19 113 15 5 16 15 15 15
580264 12 AWG 1 1 122 15 5 24 20 20 20
580182 12 AWG 1 19 132 15 5 25 20 20 20
586144 12 AWG 2 1 245 15 5 47 20 20 20
586095 12 AWG 2 19 260 15 5 49 20 20 20
583897 12 AWG 3 1 368 15 5 71 20 20 20
584533 12 AWG 3 19 390 15 5 73 20 20 20
580202 10 AWG 1 1 153 20 5 37 30 30 30
580207 10 AWG 1 19 165 20 5 39 30 30 30
580297 10 AWG 2 1 307 20 5 73 30 30 30
587251 10 AWG 2 19 326 20 5 77 30 30 30

Files & Documents

556.39 Kb | PDF


Presented By:

I-Pro Martin is proud to represent the industry's premiere manufacturers in both the commercial, industrial and utility marketplaces.

720-540-3636
4350 Wadsworth Blvd, Suite 350
Wheat Ridge, CO 80033
Top